The 100L Climatic Test Chamber is an essential testing equipment for various industries. It is made of high-quality stainless steel and PVC material that makes it durable and long-lasting. The test chambers control mode is manual, and it operates on electricity, making it easy to use. The semi-automatic operate method of this test chamber makes it easy for multiple specimens to be tested at a time. The test chambers 100L capacity allows for testing of larger specimens. This climatic test chamber can replicate different climatic conditions such as temperature and humidity. It is ideal for testing the performance of various materials and products in different environments. The test chamber can be used in the manufacturing industry, research and development labs, and quality control departments. The 100L Climatic Test Chamber is an ideal choice for businesses that require a reliable and efficient testing equipment. It is manufactured, supplied, and exported by a reputable company that ensures quality and customer satisfaction.
Model | DR-H201-100 | DR-H201-150 | DR-H201-225 | DR-H201-408 | DR-H201-1000 | |
Internal Dimension (W*H*D) | 400*500*500mm | 500*500*600mm | 500*750*600mm | 600*850*800mm | 1000*1000*800mm | |
External Dimension (sus Type) (W*H*D) | 950*1400*1100mm | 1100*1500*1100mm | 1100*1670*1200mm | 1200*1770*1400mm | 1550*2100*1400mm | |
External Dimension (paint Type) (W*H*D) | 700*1400*1100mm | 800*1500*1100mm | 800*1670*1200mm | 900*1770*1400mm | 1550*2100*1400mm | |
Temperature | -20/-40/-70 | |||||
Total Power (KW) | 4.5/4.5/6.5 | 5/5/6.5 | 9.5/9.5/11.6 | 9.5/9.5/11.6 | 17/17/21.5 | |
Maximum Current (A) | 25/25/32 | 32/32/40 | 25/32/40 | 32 | 50/50/60 | |
Voltage (A) | Sigle Phase 220V | Three Phase 380V | ||||
Performane | Temp.& Humi. Adjust Way | Balanced | (BTHC) PID intelligent adjustment||||
Temperature Range | -20,-40,-70~150 | |||||
Temperature Accuracy | 0.01 | |||||
Temperature Tolerance | 1.0or2.0 | |||||
Temperature Fluctuations | 0.5 without load and temperature stable | |||||
Temperature Uniformity | 1.5 without loading, 50mmSENSOR | |||||
Humidity Range | 20%-98%RH | |||||
Humidity Accuracy | 0.1%RH | |||||
Humidity Tolerance | 1 75%RH3%RH 2 75%RH 6%RH | |||||
Humidity Fluctuations | 2.5%RH | |||||
Heating Rate | 3/min in average | |||||
Cooling Rate | 1/min in average | |||||
Regulator | Cooling Method | Single stage compression, two stage compression | ||||
Refrigerator | Hermertically Sealed France Tecumseh Compressor or Semi-hermetic BOcK Compressor | |||||
Cooling Method | Air-cooled | |||||
Controller | Operation Panel | Programmable LCD Touch Screen | ||||
Running Mode | Fix Running, Pattern Running | |||||
Program Memory Capacity | 120 Group Programmable, Max 100 Section Each | |||||
Output | Rs-232 (USB,Optional) | |||||
Water Sup | Water Supply | Circulating Water | ||||
Water Tank Capacity | Chamber Internal Capacity < 800L: 25L X 1pc | |||||
Chamber Internal Capacity > 800L: 25LX 2pc |
Price: