UL1581 combustion testing machine

UL1581 combustion testing machine

144005.0 INR/Unit

Product Details:

  • Hardness Robust Steel Construction
  • Max Height 300 mm
  • Gas Pressure 20~100 kPa (adjustable)
  • Humidity 50% 10% RH
  • Specimen Size 300 mm 75 mm (max)
  • Display Type Digital/Analog
  • Accuracy 1 mm
  • Click to view more
X

UL1581 combustion testing machine Price And Quantity

  • 144005.0 INR/Unit
  • 1 Unit
  • Integrated Data Acquisition and Analysis
  • Adjustable, 099.9 s
  • No Vibration, No Corrosive Gas
  • Pre-set at 20/45
  • 200500 ml/min
  • Tempered Glass
  • Automatic Recording
  • 1000 mm 600 mm 800 mm (LWH)
  • Laboratory Grade Methane or Propane
  • Overheat Protection, Gas Leakage Alarm

UL1581 combustion testing machine Product Specifications

  • Laboratory, Quality Control
  • Semi-Automatic
  • Up to 5
  • Horizontal/Vertical Combustion
  • Automatic/Manual
  • Up to 75 mm
  • 3 s
  • 18 mm/s 2 mm/s
  • 0300 mm
  • Wire and Cable Flame Test Complying with UL1581
  • Touch Panel
  • Programmable Timer, Gas Flow Control, Observation Window
  • 1 mm
  • AC 220V, 50Hz
  • 220V
  • 1/4 NPT Female
  • Combustion Testing Machine
  • 15C~35C
  • Bench-top
  • 50 Hz
  • 300 mm 75 mm (max)
  • 1 mm
  • Digital/Analog
  • 300 mm
  • 20~100 kPa (adjustable)
  • 50% 10% RH
  • Approx. 65 kg
  • 300 mm
  • 1 Set
  • Robust Steel Construction
  • Integrated Data Acquisition and Analysis
  • Adjustable, 099.9 s
  • No Vibration, No Corrosive Gas
  • Pre-set at 20/45
  • 200500 ml/min
  • Tempered Glass
  • Automatic Recording
  • 1000 mm 600 mm 800 mm (LWH)
  • Laboratory Grade Methane or Propane
  • Overheat Protection, Gas Leakage Alarm

UL1581 combustion testing machine Trade Information

  • Cash in Advance (CID)
  • 100 Unit Per Month
  • 7 Days
  • All India

Product Description

STANDARD FEATURES


Burning Chamber Capacity

0.75m with glass observation door

Burning Angle

20 , 45 , 90  (ie 0 ) adjustable

Flame Time

0 ~ 99 minutes 99 seconds can be set

After Flame Time

0 ~ 99 minutes 99 seconds can be set

After Glow Time

0 ~ 99 minutes 99 seconds can be set

 

Burner Dimensions

The inner diameter of the nozzle is 9.50.3mmthe effective length of the

nozzle is 10010mm, and there is an air adjustment hole

Combustion Gas

LPG gas (Customize)

Flame Height

Adjustable from 20mm to 175mm as standard

 

 

Features

It is also equipped with lighting device, air extraction device, gas flow regulating

valve, gas pressure gauge, gas pressure regulating valve, gas flow meter, gas

U-shaped pressure gauge and sample fixture

Power

AC 220v 50HZ

The UL1581 Combustion Tester is specialized equipment designed to perform the combustion test requirements of Underwriters Laboratories (UL) Standard UL1581, Wire, Cable and Flexible Cords.The UL1581 standard covers a wide range of test methods for the combustion performance of wire and cable to ensure the reliability of these products in terms of electrical and fire safety. The tester evaluates the combustion behavior, flame retardancy and fire resistance of wires and cables by simulating actual fire conditions, and is widely used in wire and cable manufacturing, electrical equipment manufacturing, building materials and other industries. The following is a detailed description of the UL1581 Combustion Tester:

I. Main Uses
1. Compliance with standards: for the implementation of the Underwriters Laboratories (UL) standard UL1581 wire, cable and cord combustion test requirements.
2. Combustion performance test: to assess the combustion behavior of wire and cable under specific burning conditions, including burning speed, burning time, flame spread.
3. Flame Retardant Performance Test: Evaluate the flame retardant properties of wire and cable, such as self-extinguishing, drippings, smoke generation, etc..
4. Fire resistance test: Evaluate the fire resistance of wire and cable under the action of high-temperature flames to ensure that it can still maintain power transmission for a certain period of time under fire conditions.
5. Quality Control: Used in the production process of wire and cable for quality control of raw materials and finished products to ensure that the products comply with combustion and flame retardant standards.
6. Certification testing: Used for certification testing of wire and cable products to ensure that they comply with national and industry safety standards.
7. R&D and improvement: In the R&D stage, it is used to evaluate the combustion and flame retardant properties of new materials and cables, and to guide product design and improvement.

II. Working Principle
UL1581 combustion tester by simulating the burning conditions of wires and cables in an actual fire, samples of many types of combustion tests, including vertical combustion test, horizontal combustion test, FT1 combustion test, FT2 combustion test and so on. The specific steps are as follows:
1. Sample preparation: the wire and cable to be tested will be cut and pre-treated according to the standard requirements, and the length and diameter of the sample will be different according to different test methods.
2. Fixing the sample: Fix the sample on the sample holder of the testing machine to ensure that the sample is in the specified position and angle.
3. Ignition: The sample is ignited using a flame of specified size and shape. The ignition time and flame height vary according to the test method. For example, the ignition time for the FT1 combustion test is 15 seconds and the flame height is 125mm.
4. Combustion test:
- Vertical combustion test: fix the sample vertically and ignite the sample with flame to observe the combustion behavior of the sample, including combustion time, flame spreading, drippings, etc.
- Horizontal combustion test: Fix the sample horizontally, ignite the sample with flame and observe the combustion behavior of the sample, including burning speed, burning time, flame spread, etc.
- FT1 Combustion Test: Simulate the burning behavior of wire and cable in a fire to evaluate its flame retardant properties.
- FT2 combustion test: evaluate the fire resistance of wire and cable under the action of high temperature flame.
5. Evaluation of results: According to the standard requirements, the combustion behavior of the sample is evaluated to determine whether it meets the combustion and flame retardant standards. For example, UL1581 standard specifies that the burning speed of the sample should be less than or equal to 100mm/min.

Frequently Asked Questions
Q1What is the scope of application of UL1581 combustion tester?
A1: UL1581 combustion tester is suitable for testing the combustion performance of wires and cables according to UL1581 standard, including vertical combustion (VW-1, FT1), horizontal combustion (FT2), cable combustion test, etc., to evaluate the flame retardant properties and flame propagation ability of wires and cables in a fire.
. The test shall be conducted in a closed exhaust gas treatment system to prevent leakage of harmful gases.
Q2: What are the test specimen size and pretreatment requirements for UL1581 combustion tester?

A2: The length of the test sample is usually 457mm or 610mm, and the number of samples is one strip
. The marking of the flat wire should stick out close to the wide side of the wire. The sample should be pre-treated under standard environment to ensure the accuracy of test results.

Q3: How to control the flame height and burning time of UL1581 combustion tester?
A3: Flame height and burn time are accurately controlled by adjusting the methane flow meter, back pressure gauge and pressure gauge. The methane flow rate should be adjusted to 96530ml/min, the back pressure should be within 12525mm water column, and the pressure should be kept at 69-138kP
. Flame height can be adjusted by manually adjusting the inner and outer flames, or by using a precision flow meter and pressure gauge, usually in the range of 20-200mm. Flame application time can be set from 0-99.99 seconds, with a standard requirement of 15 seconds and an accuracy of 0.01 seconds.
The standard requirement is 15 seconds, and the accuracy can be up to 0.01 seconds. The equipment is equipped with automatic ignition, combustion, stop burning, timing, counting functions, can automatically complete the test process.
It can automatically complete the test process.


Versatile Testing Capabilities

Designed for both horizontal and vertical combustion tests, the UL1581 combustion testing machine allows evaluation across a test range up to 300 mm in length and specimens up to 75 mm wide. The programmable timer and accurate measurement systems ensure repeatable and dependable results for compliance and research purposes.


Safety and User-Friendly Design

Equipped with an overheat protection system, gas leakage alarm, and tempered glass observation window, the machine prioritizes operator safety. The touch panel interface, automatic/manual control modes, and large observation area make operation straightforward and efficient, ideal for busy laboratory settings.


Seamless Data Acquisition and Analysis

Integrated data acquisition and analysis software streamlines the recording of afterflame times and other critical measurements. Digital and analog display options provide versatile readouts, while automated recording reduces manual errors, making test result management effortless.

FAQ's of UL1581 combustion testing machine:


Q: How does the UL1581 combustion testing machine ensure operator safety during testing?

A: The machine is designed with several safety features, including tempered glass observation windows, overheat protection, and a gas leakage alarm, providing a secure environment throughout the testing process.

Q: What is the primary application of this combustion testing machine?

A: It is primarily used for wire and cable flame tests in accordance with UL1581 standards, making it essential for quality control, certification, and research in cable manufacturing and related industries.

Q: When should the integrated data acquisition and analysis software be used?

A: This software should be utilized during every test to automatically record ignition and afterflame times, streamlining documentation and enhancing the accuracy of results.

Q: Where can the UL1581 combustion testing machine be installed?

A: The equipment is designed as a bench-top unit ideal for laboratory settings, provided that the ambient conditions are free of vibration and corrosive gases, with controlled humidity and temperature.

Q: What is the process for conducting a flame test on this machine?

A: Specimens are mounted in the chamber, ignition time is set (0-99.9s adjustable), burner angle selected (20 or 45), and airflow rate adjusted. The test is started using the automatic or manual mode, with afterflame timing and data recorded automatically.

Q: How does the machine accommodate varying test requirements?

A: With adjustable gas pressure, programmable timer, airflow rate control, and a selection of automatic or manual modes, the machine easily adapts to different test parameters and specimen sizes up to 300 mm 75 mm.

Q: What are the benefits of using this machine for UL1581 compliance testing?

A: Users benefit from automated data capture, reliable safety features, repeatable test accuracy, and complete compliance with international wire and cable flame test standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Environment Test Chamber' category



Back to top