Product Description
Products parameter:
Temperature control range | 20 ~ 93 C; Resolution: 0.1 C |
Humidity control range | a,Light cycle: 10 ~ 85RH%; Resolution: 0.1RH% b,Dark cycle: 30 ~ 100RH%; Resolution: 0.1RH% |
Standard blackboard thermometer | 35 ~ 125 C; Resolution: 0.1 C |
Blackboard thermometer (optional) | 35 ~ 120 C; Resolution: 0.1 C |
Test time control range | 10000h |
Irradiance control range | 0.6~3.08W/m2@420nm; (300-400nm) |
Accuracy | 0.02W/m2@420nm; |
Xenon arc lamp rated power | 6kW |
Sample clip distribution diameter | 550mm |
The size and number of specimen holders can be loaded | 33 national standard, 20 American standard |
Timing of each sample holder | 10000h |
Light cycle | 1000h |
Spraying cycle | 1000h |
Dimensions | 1200 900 1800mm |
Weight | 350kg |
Power source | AC380V 50Hz 10kW. |
The core function of xenon lamp aging test chamber
one
Simulate solar spectrum
Using a xenon lamp light source, covering ultraviolet (UV), visible light, and infrared (IR), the spectral distribution closest to natural sunlight.
Wavelength range: 290nm~3000nm, adjustable irradiation intensity (e.g. 0.5~1.5 W/m @ 340nm).
two
Environmental parameter control
Temperature range:- 20 C to+100 C (some models support higher temperatures).
Humidity range: 10%~98% RH.
Spray function: Simulate rainwater erosion (optional).
three
Test standard compatibility
Compliant with international and industry standards such as ASTM G155, ISO 4892, SAE J2527, GB/T 16422, etc.
Selection guide for xenon lamp aging test chamber
1. Select by application scenario
Basic type: suitable for conventional material aging testing (such as plastics, coatings).
High irradiance type: Accelerated testing (such as photovoltaic modules, automotive exterior).
Multi functional type: integrated temperature/humidity/spray/dark cycle (such as textiles, rubber).
2. Key parameter reference
Xenon lamp power: commonly 1.8kW, 3kW, 6kW, the higher the power, the higher the irradiation intensity.
Sample capacity: Select the volume according to the testing requirements (such as 50L, 150L, 500L).
Control system: touch screen operation, data recording, remote monitoring (intelligent and more efficient).